Hunter X-Core Owners Manual And Programming Instructions page 118

Residential irrigation controller
Table of Contents

Advertisement

sensor alarms (ClIK sensors sen 1–4 only) ..........................
Whenever a sensor alarms (changes to Open from its
Normally Closed state), an ATTENTION message appears
in the display if a program response has been configured
for that sensor.
Details for each sensor alarm will be found in the Alarm
Log (Data History dial position). If the sensor response
is changed to Pause or Suspend, and the sensor has not
been connected to the corresponding sensor terminals,
the sensor will remain active, and cause a sensor alarm.
If the sensor is set to OFF for all programs, it will not
cause an alarm or ATTENTION display.
However, the state of the sensor may be observed at
the Advanced Features dial position, Utility Functions,
and then View Sensor Status. The screen will explain if
the sensor is in a closed or open state. If the sensor's
response was set to suspend or pause in the Set Sensor
Operation dial position, the display will also show an alarm
message in this screen if the circuit is open. You can also
see the state of the sensor, even with the sensor response
set to "OFF," in the Set Sensor Operation dial position.
32
If a Program configured for shutdown by that sensor was
active when the alarm occurred, it will either Suspend or
Pause as configured.
CleAr MeSSAGe
Press the + button to clear the alarm message,
and view the status of the programs. Pressing + only
clears the message, not the alarm. The display will then
show the status of Programs in response to the sensor.
Programs that were Suspended will continue to show the
stations and count down the time remaining, but will say
SUSPEND along with automatic program letter and no
watering will occur. If the sensor is reset, they will resume
watering instantly where they should be in real time.
Programs that were Paused by the sensor will show the
Program letter and Pause, and the time remaining will be
frozen . No count down occurs because events are Paused.
If the sensor is reset, the Paused Programs will resume
instantly, wherever they left off when the alarm occurred.