mounTing The reCeiver
Wiring the receiver to a hunter X-Core, pro-C,
iCC and i-Core
1. Remove the sensor jumper across the two
SEN terminals in the controller.
2. Attach the two yellow wires to the 24
VAC terminals.
3. Attach the blue wire to one SEN terminal and
the white wire to the other SEN terminal.
Red light indicates
SENSOR BYPASS
sensor is bypassed
GREEN = Sensor is dry
SENSOR STATUS
RED = Sensor is wet
Press to bypass, press
again to re-enable
RAIN SENSOR BYPASS
C
P MV
B
SEN
W
SEN
TEST
REM
Y
AC
Y
AC
G
Wiring the receiver to a hunter aCC
1. Connect the blue and white wire to any of
the four Sensor Terminal pairs (Sen 1 shown).
2. Attach yellow wires to 24VAC and COM
terminals.
3. Use features at the "Set Sensor Operation"
dial position on ACC to complete setup.
4. See ACC owner's manual for further details.