Hunter X-Core Owners Manual And Programming Instructions page 156

Residential irrigation controller
Table of Contents

Advertisement

• Use the – or + buttons to step backward and forward
through the Controller Log to track the S-Sync
changes. Each log will show the date and time, and the
Before and After settings for Seasonal Adjustment.
• If the controller has been operating unattended for
period of time, the performance of the Solar Sync
adjustments can be verified in this manner.
• If a user changes the Solar Sync setup (either Region
or Water Adjustment), this is also tracked in the
Controller Log. It will also show the Before and After
settings, but the log will show S-Sync Setup Changed
At Controller. This means it was changed by a human
operator.
• There may not be a Solar Sync log for each day! If the
weather conditions are stable and the Solar Sync does
not need to change, there will not be a log entry for the
day. The logs are only created when Solar Sync makes
a change to the Seasonal Adjustment settings.
• The Controller Log will store the most recent 250
controller events. The amount of other controller log
activity will determine how many days of Solar Sync
history are available.
70
SOlAr-SynC SenSOr AlArMS
S-Sync RAIN ALARM, S-Sync TEMP ALARM
• If the Solar-Sync sensors have been mapped to the
Sensor 1-4 inputs on the controller, and one of the
Solar-Sync sensors (Rain or Temp) detects an alarm
condition, the display will show : ATTENTION S-Sync
RAIN (or TEMP) ALARM
• This means that rain or near-freezing conditions
have suspended irrigation (as set in the Set Sensor
Operation dial position) until the alarm is cleared.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents