ACC can therefore run automatic programs, manual
station and programs, and ICR commands simultaneously.
Each running event will be shown on the display with
the reason for running (programs will be shown with the
program letter followed by "ICR" if they were started by
the remote), and the remaining time for the event.
The display shown here is possible with ACC: six events
are running, including ICR station starts (ICR), ICR
program starts (A-ICR), manual single-stations (MAN),
manual program starts (C-MAN), and an automatic
program (D-AUTO).
If simultaneous operation is not desired, press the
Off button on ICR before starting another program or
station. Off will stop everything the controller is running,
regardless of what started it.
Stacking and SmartStack rules are not observed when
manual single station ICR commands are sent to the ACC.
Stacking and SmartStack rules do apply when manual
program ICR commands are sent to the ACC. If a program
ConneCTInG To Imms .................................................................
hunTer IrrIGaTIon manaGemenT and monITorInG sysTem
ACC controllers can upgraded to provide full two-way
communications with central control software (IMMS 2.0).
The ACC Com modules are installed in place of the logo
badge on wall mount controllers, and under the facepack
door in a special bracket (APPBRKT) in pedestal units.
ACC controllers can be connected with hardwired cable
(GCBL), dial-up telephone (POTS or "plain old telephone
service"), or GSM cellular communications (using Circuit
Switched Data or CSD).
Multiple controllers can share a connection, with
additional runs of hardwired cable or UHF radio
communications. Advance to Daylight Saving and use +/-
to select YES.
No tee splices are permitted within the GCBL and all
hardwired devices must be in one single continuous wire
run.
17
Figure 3
is not set to overlap, the ICR command will be ignored
when trying to start the manual program.
ICR manual single station commands will be obeyed
if the controller is in the OFF position, or in a sensor
shutdown mode. ICR manual program commands will
NOT be obeyed and will be ignored in the OFF position. If
the controller is in a sensor shutdown mode and an ICR
command is sent to activate a program, the ACC will obey
the sensor shutdown if that program is assigned to pause
or suspend according to the sensor. The manual program
ICR command will be shown in the display as in pause or
suspend mode, depending on how you have your sensor
programmed. (Fig 3) If the program that you are trying to
manually start with an ICR command is not programmed
to pause or suspend a sensor, the command will be obeyed
and the program will run.
If you are utilizing a simultaneous station group, or SSG,
you may run an individual station that is included in the
SSG. The fact that the station is included in the SSG will be
ignored, and you may run that station by itself.
DIAl-uP telePhOne (ACC-COM-POtS)
Connection must be within 6 ft (2 m) of the telephone
company connection, via standard RJ-11 jack..
IMMS 2.0 and dial-up Com modules require analog lines
with dial tone. These products do not have digital dialing
capabilities.
Dial-up must be via dedicated line. The controller will
always answer on the first ring and must not share with
fax machines or other devices.