Hunter X-Core Owners Manual And Programming Instructions page 59

Residential irrigation controller
Table of Contents

Advertisement

HIdden feaTUres (continued) ............................................................................................
Easy Retrive
Program Memory
The Pro-C is capable of saving the preferred watering program into
memory for retrieval at a later time. This feature allows for a quick way of
resetting the controller to the original programmed watering schedule.
To save the program into memory.
1. With the dial in the RUN postiion, press and hold the
buttons for 5 seconds. The display will scroll
across the display indicating the program is being saved into memory.
2. Release the
and
buttons.
To retrieve a program that was previously saved into memory.
1. With the dial in the RUN position, press and hold the
buttons for 5 seconds. The display will scroll
across the display indicating the program is being saved into memory.
2. Release the
and
buttons
Hunter Quick Check
This circuit diagnostic procedure is can quickly identify "shorts"
commonly caused by faulty solenoids or when a bare common wire
touches a bare station control wire.
To initiate the Hunter Quick Check test procedure:
1. Press the
,
,
and
mode, the LCD will display all segments (helpful when troubleshoot-
ing display problems).
2. Press the
button to begin the Quick Check test procedure. The
system will search all stations to detect a high current path through
the station terminals. When a field wiring short is detected, an ERR
symbol preceded by the station number will momentarily flash on
the controller LCD display. After the Hunter Quick Check completes
running this circuit diagnostic procedure, the controller returns to
the automatic watering mode.
and
from left to right
and
from right to left
buttons simultaneously. In the standby
Clearing Controller's Memory/Resetting Controller
If you feel that you have misprogrammed the controller, there is a
process that will reset the memory to factory defaults and erase all
programs and data that have been entered into the controller. Press and
hold the
button. Press and release the RESET button on the back of
the front panel. Wait until the display shows 12:00am. Release the
button. All the memory has been cleared and the controller may now be
reprogrammed.
WINTERIZING YOUR SYSTEM
In regions within the country where the frost level falls below the
depth of the installed piping, it is common for these systems to be
"winterized". Several methods can be used to drain the water from the
system. If the blow out method is used it is recommended that a qualified
licensed contract perform this type of winterization.
WARNING! WEAR ANSI APPROVED SAFETY EYE PROTECTION!
Extreme care must always be taken when blowing out the system with
compressed air. Compressed air can cause serious injury, including
serious eye injury from flying debris. Always wear ANSI approved safety
eye protection and do not stand over any irrigation components
(pipes, sprinklers, and valves) during blow out. SERIOUS PERSONAL
INJURY MAY RESULT IF YOU DO NOT PROCEED AS RECOMMENDED.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents