Connecting A Pump Start Relay - Hunter X-Core Owners Manual And Programming Instructions

Residential irrigation controller
Table of Contents

Advertisement

CoNNECTING a pUmp sTarT rElay

NoTE: Complete this section only if you have a
pump start relay installed. A pump start relay is
a device that uses a signal from the controller to
actuate a separate electrical circuit to energize a
pump to provide water to your system.
The controller should be mounted at least a 15 ft (4.5 m) away from
both the pump start relay and pump to minimize any potential
electrical interference.
1. Route a pair of wires from the pump relay into the controller.
2. Connect a common wire to the C (Common) terminal inside the
controller and connect the remaining wire from the pump start
relay to the P (Pump) terminal.
Relay holding current draw must not exceed 0.3 A. Do not connect
the controller directly to the pump or damage to the controller will
result.
10
PSR Series
Pump Start Relay
To Pump
15 ft Minimum (4.5 m)