Configuration
February 2023
2. Enter any of the following as needed:
3. When you have finished making changes, select Send to update the device
2.10
Advanced options
The following optional, advanced functionality is available to view calibration history for the
sensor, set reminders to perform maintenance at regular intervals, and to reset or restore
device settings.
2.10.1
Service reminders
You can configure service reminders for regular maintenance tasks such as calibration,
bump testing, power module replacement, and sensor replacement. The device issues an
82
•
Long tag: Enter an identifier for the device up to 32 characters long. The Long
Tag field is blank by default and does not display if left blank.
•
Tag: Enter an identifier for the device up to eight uppercase alphabetic and
numeric characters long. The Tag field is blank by default and does not display if
left blank.
•
Descriptor: Enter a description of the device up to 16 characters long. The
Descriptor field is blank by default and does not display if left blank.
•
Message: Enter text up to 32 characters long. The Message field is blank by
default, does not display if left blank, and may be used for any purpose.
•
Date: Enter a date in mm/dd/yyyy format. The date may be used for any purpose,
such as recording the date of the most recent calibration.
configuration.
Reference Manual
00809-0100-4928
Emerson.com/Rosemount