Sign In
Upload
Manuals
Brands
Emerson Manuals
Measuring Instruments
Daniel 3812
Emerson Daniel 3812 Manuals
Manuals and User Guides for Emerson Daniel 3812. We have
3
Emerson Daniel 3812 manuals available for free PDF download: Installation Manual, Maintenance And Troubleshooting Manual
Emerson Daniel 3812 Installation Manual (142 pages)
liquid ultrasonic flow meter
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 2.74 MB
Table of Contents
Important Safety Instructions
5
Table of Contents
9
Section 1: Introduction
15
Typical Applications
15
Features and Benefits
16
Acronyms, Abbreviations and Definitions
17
Table 1-1 Acronyms, Abbreviations and Definitions
17
Rev H June
19
Daniel Meterlink Software
20
Figure 1-1 Daniel Meterlink Download and Registration
20
Daniel 3812 Liquid Ultrasonic Flow Meter Design
21
Figure 1-2 Direct Mount Electronics Assembly with Split Shroud
21
Figure 1-3 Direct Mount Electronics with Latched Single Band Shrouds and Remote Display
22
Figure 1-4 Direct Mount Electronics with Bolted Single Band Shrouds and Local Display
23
Figure 1-5 Direct Mount Electronics Assembly with Clamped Band Shrouds
24
Figure 1-6 Remote Mount Electronics Assembly with Clamped Band Shrouds
25
Figure 1-7 Remote Mount Electronics Assembly with Split Shrouds
26
Figure 1-8 Optional Local Display and Glass Endcap
27
Meter Specifications
28
Table 1-2 Meter Specifications
28
Pre-Installation Considerations
32
Safety
32
Daniel 3812 Certifications and Approvals
34
FCC Compliance
34
Section 2: Mechanical Installation
35
Meter Piping, Lifting and Mounting
35
Figure 2-1 Direct Mount Meter Electronics Assembly with Split Shroud
38
Figure 2-2 Remote Mount Meter Electronics Assembly with Split Shroud
39
Figure 2-3 Direct Mount Meter Electronics with Bolted Band Shrouds
40
Table 2-1 3812 Ultrasonic Meter Shrouds Options Per ANSI Pressure Rating
41
Figure 2-4 Direct Mount Meter Electronics Assembly with Clamped Band Shrouds
41
Piping Recommendations
42
Figure 2-5 Piping Recommendations Unidirectional Flow
43
Figure 2-6 Piping Recommendations Bidirectional Flow
44
Table 2-2 Piping Recommendation for Uni-Directional or Bi-Directional Flow
45
Meter Safety for Hoist Rings and Lifting Slings
46
Use of Appropriate Safety Engineered Swivel Hoist Rings in Meter End Flanges
47
Figure 2-7 Meter End Flange with Tapped Flat-Counterbore Hole for Hoist Ring
47
Figure 2-8 Safety Approved Hoist Ring and Non-Compliant Eye Bolt
48
Figure 2-9 90 Degree Angle between Slings
49
Figure 2-10 Sling Contacting Electronics Enclosure
50
Table 2-3 Hoist Ring Part Number Lookup Table
53
Table 2-4 Hoist Ring Lookup Table for Daniel Model 3812 Liquid Ultrasonic Flow Meters
53
Appropriately Rated Lifting Slings
54
Figure 2-11 Correct Sling Attachment
55
Figure 2-12 Incorrect Sling Attachment
56
Mounting Requirements in Heated or Cooled Pipelines
57
Section 3: Electrical Installation
59
Cable Length TTL Mode
59
Cable Length Open Collector Mode
59
Table 3-1 Configurations for Open Collector Frequency Outputs
59
Grounding Meter Electronics Housing
60
Figure 3-1 Transmitter Electronics Enclosure Internal Chassis Ground
60
Conduit Seals
61
Figure 3-2 External Ground Lug
61
Startup for Systems Using Explosion-Proof Conduit
62
Startup for Systems that Use Flame-Proof Cable
63
Wiring and I/O
64
CPU Module Labeling and LED Indicators
65
Figure 3-3 CPU Module Labeling and LED Indicators
65
Table 3-2 CPU Module Labeling and LED Functions
66
Table 3-3 Ethernet Cable to PC Communication
67
Table 3-4 Serial Port a Parameters
68
I/O Connections
69
Figure 3-4 PC to Meter Serial Connection Wiring
69
Figure 3-5 CPU Module I/O Connections
69
Frequency/Digital Outputs
70
Figure 3-6 CPU Module - Frequency/Digital Outputs Common Ground
72
Table 3-5 Frequency/Digital Outputs Possible Configurations
72
Analog Input Settings
74
Analog Output Settings
74
DHCP Server Switch Settings
74
Digital Input
74
Table 3-6 DHCP Server Switch Settings
74
Configuration Protect Switch Settings
75
External Power Source Connection and Fuse
75
Table 3-7 Configuration Protect Switch Settings
75
Security Seal Installation
76
Direct or Remote Mount Transmitter Electronics Enclosure Seal
76
Base Enclosure Security Seals
78
Seal the Junction Box Remote Mount Electronics Option
79
Bolted Band Shroud Security Seals
80
Clamped Band Shroud Security Seals
81
Split Shroud Security Seals
82
Latched Band Shroud Security Seals
83
Seal Conduit Ports
85
Section 4: Configuration
87
Daniel Meterlink Setup
87
Field Setup Wizard
88
Table 4-1 Local Display Labels, Descriptions and Valid Units
89
Using AMS Device Manager to Configure the Meter
93
Figure 4-1 AMS Device Description Search
94
Figure 4-2 AMS File Download Complete
95
Figure 4-3 AMS Device Manager
96
Figure 4-4 AMS Device Manager - Overview
97
Figure 4-5 AMS Device Manager - Guided Setup
98
Figure 4-6 AMS Device Manager - Service Tools All Variables Status Indicators
100
Figure 4-7 Display Meter K-Factors
101
Figure 4-8 AMS Device Manager - Configure Manual Setup
102
Figure 4-9 Gating Configuration Parameter Edge Gated, Active High
104
Figure 4-10 Gating Configuration Parameter Edge Gated, Active Low
104
Figure 4-11 Gating Configuration Parameter State Gated, Active High
104
Figure 4-12 Gating Configuration Parameter State Gated, Active Low
105
Figure 4-13 Configure Flow Analysis Alert
105
Figure 4-14 AMS Device Manager - Service Tools Alerts
107
Figure 4-15 Configuration Changes Dialog
108
Figure 4-16 AMS Device Manager - Service Tools
108
Figure 4-17 AMS Device Manager - Service Tools All Variables
109
Figure 4-18 AMS Device Manager - Service Tools Trends
110
Using a Field Communicator to Configure the Meter
112
Figure 4-19 3812 Transmitter Field Wiring Conduit Entries
113
Figure 4-20 Field Communicator Wiring Diagram for the 3810 Series Electronics
114
Security Seals for the Meter
115
Appendix A: Engineering Drawings
117
Daniel 3812 Liquid Ultrasonic Flow Meter Drawings
117
Appendix B: Open Source Licenses
122
Table B-1 Open Source Licences
122
GNU General Public License
123
GNU Lesser General Public License
134
BSD Open Source License
138
M.I.T License
139
B.4 M.I.T License
139
Appendix C Index
140
C.1 Manual Index
140
Advertisement
Emerson Daniel 3812 Maintenance And Troubleshooting Manual (104 pages)
Liquid Ultrasonic Flow Meter
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 7.44 MB
Table of Contents
Table of Contents
7
Section 1: Routine Maintenance
13
Meter Maintenance
13
Field Hydrostatic Pressure Testing Procedures
15
Routine Maintenance
16
Maintenance Logs and Reports
16
Figure 1-2 Maintenance Log Collection Parameters
16
Figure 1-3 Trend Log Collection
17
Figure 1-4 Archive Log Collection Parameters
18
Pipeline Cleaning Maintenance
19
Section 2: Troubleshooting
21
Meter Status Alarms
21
Figure 2-1 Meter Monitor (Summary) View
21
Figure 2-2 Status Summary
21
Check Status
22
System Alarm
22
Figure 2-3 Meter Monitor Status Summary
22
Chord a and Chord B Alarm
23
Field I/O Alarm
23
Validity Alarm
23
Comms Alarm
23
Communications
23
Troubleshooting the Meter
24
Meter Maintenance
30
Figure 2-4 Meter Monitor (Summary) View
30
Unable to Connect Direct Serial or External Serial Modem
36
Unable to Connect to Meter
36
Ethernet Connections
37
Direct Serial Connections
37
Troubleshoot Maintenance Log Files and Trend Files
38
Files Do Not Appear in Workbook
38
Microsoft® Excel® Log/Export Options Are Not Available
38
Maintenance Logs or Trend Files Are Not Created
39
Figure 2-5 Excel® 2000 Tools Menu
39
Figure 2-6 Excel® Trusted Access Setting
40
Figure 2-7 Excel® 2007 Tools Menu
40
Figure 2-8 Excel® 2007 Developer Tab - Macro Security
41
Windows® XP with Security Update
42
Section 3: Meter Maintenance
43
Maintenance
43
Figure 3-2 Flange Stabilizers
44
Transducer Field Removal and Installation Procedure
47
Figure 3-3 LT-10 and LT-11 Transducer Assembly
47
Transducer Removal
48
Figure 3-4 Tools Required
48
Figure 3-5 Conduit Removal
49
Figure 3-6 Transmitter Electronics Enclosure and Base Enclosure Security Seal Removal
50
Figure 3-7 Transmitter Electronics Enclosure Removal
50
Figure 3-8 Acquisition Module Cable and Transducer Wiring
51
Figure 3-9 Base Enclosure Removal
52
Figure 3-10 Shroud Security Seal Removal
53
Figure 3-11 Shroud Removal
54
Figure 3-12 Transducer and Cable Disassembly
55
Figure 3-13 Feed-Thru Cable Seal Removal
55
Figure 3-14 Transducer Removal
56
Figure 3-15 LT-10 Transducer and Cable Assembly Removed from Meter
56
Figure 3-16 Upper Shroud Cable Seal
57
Figure 3-17 Cable Removal from Meter
57
Transducer Installation
58
Figure 3-18 LT-10 or LT-11Transducer Assembly
58
Figure 3-19 Transducer, Cable and Components Assembly
59
Figure 3-20 Transducer Cable Installation
60
Figure 3-21 Upper Shroud Feed-Thru Cables
61
Figure 3-22 Base Enclosure Installation
62
Figure 3-23 Transducer Terminal Block Wiring
63
Figure 3-24 Transducer Wiring and Acquisition Cable Reassembled
64
Figure 3-25 Lower Shroud Installation
65
Transducer Housing Removal and Installation Procedure
66
Transducer Housing Removal
67
Figure 3-26 Transducer Housing Removal
69
Transducer Housing Installation
70
Figure 3-27 Transducer Installation
71
Figure 3-28 Upper Shroud Feed-Thru Cable Seal
72
Figure 3-29 Transducer Terminal Block Wiring
73
Figure 3-30 Transducer Wiring and Acquisition Cable Reassembled
74
Figure 3-31 Lower Shroud Installation
75
Replace the Meter Electronics
76
Figure 3-32 3810 Series Electronics
76
Replace CPU Module or Optional I/O Module (Future)
77
Figure 3-33 CPU or Optional I/O Module (Future) Replacement
77
Figure 3-34 Transmitter Electronic Enclosure Security Seals
78
Fuse Replacement
79
Figure 3-35 Fuse Holder Cap
79
Replace Backplane, I.S. Barrier or Power Supply Board
80
Figure 3-36 Backplane Board Replacement
81
Figure 3-37 I.S. Barrier Board Replacement
83
Figure 3-38 Transmitter Electronic Enclosure Security Seals
84
Figure 3-39 Power Supply Board Replacement
85
Acquisition Module Replacement
87
Figure 3-40 Conduit Removal
87
Figure 3-41 Transmitter Electronics Enclosure and Base Enclosure Security Seal Removal
88
Figure 3-42 Transmitter Electronics Enclosure Removal
88
Figure 3-43 Acquisition Module Cable and Transducer Wiring
89
Appendix A: Conversion Factors
91
Conversion Factors Per Units of Measurement
91
K Factor Conversions
92
Appendix B: Engineering Drawings
93
Daniel 3812 Liquid Ultrasonic Flow Meter Drawings
93
Appendix C: Index
99
C.1 Manual Index
99
Emerson Daniel 3812 Installation Manual (110 pages)
Liquid Ultrasonic Flow Meter, for Direct and Remote Mount Meter Electronics
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 5.96 MB
Table of Contents
Table of Contents
9
Chapter 1 Introduction
11
General Overview of Daniel 3812 Liquid Ultrasonic Flow Meter
11
Typical Applications
11
Features and Benefits of this Product
12
Acronyms, Abbreviations and Definitions
12
Daniel Meterlink Software
15
Daniel 3812 Liquid Ultrasonic Flow Meter Design
16
Meter Specifications
20
Pre-Installation Considerations
26
Safety Conditions
26
Certifications and Approvals
27
FCC Compliance
28
Chapter 2 Mechanical Installation
29
Meter Piping, Lifting and Mounting
29
Meter Components
30
Piping Recommendations
34
Meter Safety for Hoist Rings and Lifting Slings
37
Mounting Requirements in Heated or Cooled Pipelines
44
Chapter 3 Electrical Installation
45
Cable Length TTL Mode
45
Cable Length Open Collector Mode
45
Grounding Meter Electronics
46
Conduit Seals
47
Wiring and I/O
49
Daniel Ultrasonic Meters I/O Connections
55
Security Seal Installation
60
Chapter 4 Configuration
69
Daniel Meterlink Setup
69
Using AMS Device Manager to Configure the Meter
74
Using a Field Communicator to Configure the Meter
89
Security Seals for the Meter
91
Appendix A Engineering Drawings
93
Daniel 3812 Liquid Ultrasonic Flow Meter Drawings
93
Appendix B Open Sources Licenses
95
Advertisement
Advertisement
Related Products
Emerson Daniel 3814
Emerson Daniel 3818
Emerson Rosemount 3051 CF Series
Emerson Daniel 3417
Emerson Daniel 3416
Emerson Daniel 3410 Series
Emerson Daniel 3414
Emerson Daniel 3412
Emerson Daniel 3418
Emerson Rosemount 3051SAL
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL