Appendix A

SPECIFICATIONS

General
Product
Measurement principle
Reference Conditions
Microwave Output Power
CE-mark
Upstart time
Display / Configuration
Integral Display
Output Units
Output Variables
HART device for remote confifguration
PC for remote configuration
Electric
Power supply
Output
Signal on alarm
Saturation levels
IS parameters
Cable entry
Output Cabling
www.rosemount.com
Reference Data
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-13
Rosemount Series 3300 Guided Wave Radar Level and Interface
Transmitter;
Model 3301 for Level (Interface available for fully immersed probe).
Model 3302 for Level and Interface.
Time Domain Reflectometry (TDR).
Twin Lead probe, 77 °F (25 °C) water
Nominal 50 µW, Max. 2 mW.
Complies with applicable directives (R&TTE, EMC, ATEX)
< 10 s
The integral display toggles between the following variables: level,
distance, volume, internal temperature, interface distance, interface level,
peak amplitudes, interface thickness, percent of range, analog current
output.
Note! The Integral Display can not be used for configuration purposes.
For Level, Interface and Distance: ft, inch, m, cm or mm.
For Volume: ft
Model 3301: Level, Distance (to product surface) and Volume. With fully
immersed probe: Interface Level and Interface Distance.
Model 3302: Level, Distance (to product surface), Volume, Interface Level,
Interface Distance and Upper Product Thickness.
Rosemount hand-held communicator Model 275.
Radar Configuration Tools software package.
Rosemount AMS software.
Loop-powered (2-wire), 11 - 42 VDC (11 -30 VDC in IS applications, 16-42
VDC in Explosion Proof/Flame Proof applications).
Analog 4 - 20 mA, HART.
Standard: Low=3.75 mA. High=21.75 mA.
Namur NE 43: Low=3.60 mA. High=22.50 mA.
Standard: Low=3.9 mA. High=20.8 mA.
Namur NE 43: Low=3.8 mA. High=20.5 mA.
U
= 30 V,l
i
½ - 14 NPT for cable glands or conduit entries. Optional: M20 x 1.5
conduit/cable adapter or PG 13.5 conduit/cable adapter.
Twisted shielded pairs, 18-12 AWG..
Rosemount 3300 Series
3
3
, inch
, US gals, Imp gals, barrels, yd
= 130 mA, P
= 1 W, L
=0, C
=0.
i
i
i
i
3
3
, m
or liters.