Electrical system
TABLE B - COIL AND LEFT CYLINDER CON-
NECTION
•
Check that the HV cable with grey mark
(left engine head) is well inserted in the
coil with grey mark on the connector
TABLE C - COIL AND RIGHT CYLINDER CON-
NECTION
•
Check that the HV cable without grey
mark (right engine head) is well inser-
ted in the front coil
TABLE D - PROCEDURE FOR CORRECTLY FITTING THE ABS CONTROL UNIT CONNECTOR
•
The initial position of the connector fastener lever must be as shown in the figure
TABLE D1
•
Place the connector on the opposite
side of the control unit and lower the
driving lever until the "click" that signals
the end of the stroke is heard.
ELE SYS - 84
V7 III ABS