2. Negative signal sensor (green/white)
3. Heater ground (white/yellow)
4. Heater power (red/brown cable)
Diagnostic tool - Parameters and statuses
Oxygen sensor voltage RH - (mV)
Right lambda probe - (---, Not enabled,
Not active (start), Not active (heat.),
Not active (rich), Operating, Not active
(lean), Fault
Diagnostic tool - Activation
Lambda probe heater 2
Diagnostic tool - Electrical errors
Control of the air-fuel ratio / Right lambda probe P0150 - positive short circuit / open circuit, short
circuit to negative / signal not valid.
Error cause
Short-circuit to positive: excessive voltage at PIN 18 or PIN 12 of the control unit connector.
Open circuit or short-circuit to negative: interruption of the circuit or null voltage between
control unit connector PIN 18 and 12
Troubleshooting
Short-circuit to positive:
Disconnect the control unit connector and the sensor connector.
Verify that there is no short to battery positive on sensor connector PIN 1 (corresponding to
control unit connector PIN 18); if there is a short, restore the wiring harness.
Verify that there is no short to battery positive on sensor connector PIN 2 (corresponding to
control unit connector PIN 12); if there is a short, restore the wiring harness.
Open circuit:
Disconnect the control unit connector and the sensor connector.
Verify continuity of the wiring harness between the sensor connector and the control unit
connector: Control unit PIN 18 - sensor PIN 1 and control unit PIN 12 - sensor PIN 2. If
necessary, restore the wiring harness.
If the wiring harness is intact and the error persists, proceed with the following checks.
Short-circuit to negative:
Disconnect the sensor connector and the control unit connector.
Check the sensor connector PIN 1 ground insulation. In the absence of insulation restore
the wiring harness.