Electrical system
Disconnect the right injector connector, turn the key to ON and activate the component
through the diagnostic tool.
Verify the presence of voltage at the ends of the right injector connector; if there is no voltage,
restore the wiring harness, otherwise proceed with the following checks.
Open circuit:
Carry out the check procedure of the right injector and control unit connectors.
Verify continuity of the wiring harness between the control unit connector and the right in-
jector connector (control unit PIN 32 - right injector PIN 2). In the absence of continuity
restore the wiring harness.
LEFT INJECTOR
Level in electrical circuit diagram:
Coils and injectors
Left injector position:
On the intake manifold
Connector: on injector
Electrical specifications
14.8 Ohm +/- 5% (at 20 °C - 68 °F)
Pin-out:
1. Power 12V (red/brown)
2. Ground (grey/black)
Diagnostic tool - Parameters and statuses
Injection time cyl. LH - (ms)
Diagnostic tool - Activation
Left injector
Injector control
Diagnostic tool - Electrical errors
Left injector P0201 - shorted to positive / shorted to negative / open circuit.
Error cause
Short-circuit to positive: excessive voltage at PIN 34 of the control unit connector
Short-circuit to negative: zero voltage at PIN 1 of the left injector connector
Open circuit: circuit interruption
Troubleshooting
Short-circuit to positive:
Disconnect the left injector connector, turn the key to ON and activate the component
through the diagnostic tool.
ELE SYS - 126