Diagnostic tool - Errors screen page
This display shows potential errors detected in the
vehicle (ATT) or stored in the control unit (MEM)
and it allows to check error clearing (STO).
Diagnostic tool - Adjustment
This screen page is used to adjust some control
unit parameters
Resetting
Downloading Mem Data
Self-adaptive parameters reset
Diagnostic tool - Electrical errors
Air pressure sensor P0105 - short circuit to positive / open circuit, short circuit to negative, signal not
valid
Cause of error
Malfunction of sensor inside the control unit
Troubleshooting
Replace the control unit
Air temperature sensor P0110 - short circuit to positive, open circuit / short circuit to negative
Cause of error
Malfunction of sensor inside the control unit
Troubleshooting
Replace the control unit
Error EEPROM P0601 - circuit not working