Access to On-Chip Peripheral Modules

On-chip peripheral modules are accessed in two states or three states. The data bus width is 8 bits,
so access is by byte size only. This means that for accessing word data, two instructions must be
used.
Two-state access to on-chip peripheral modules
Figure 2.12 shows operation timings for accessing on-chip peripheral modules in 2 states.
ø or ø
SUB
Internal address bus
Internal read signal
Internal data bus
(read access)
Internal write signal
Internal data bus
(write access)
Figure 2.12 On-Chip Peripheral Module Access Cycle (2-State Access)
Three-state access to on-chip peripheral modules
Figure 2.13 shows operation timings for accessing on-chip peripheral modules in 3 states.
Bus cycle
T
state
1
Address
Read data
Write data
T
state
2
43