Operation; A/D Conversion Operation; Start Of A/D Conversion By External Trigger Input; Interrupts - Hitachi H8/3637 Hardware Manual

H8/3637 series
Table of Contents

Advertisement

12.3

Operation

12.3.1

A/D Conversion Operation

The A/D converter operates by successive approximations, and yields its conversion result as 8-bit
data.
A/D conversion begins when software sets the A/D start flag (bit ADSF) to 1. Bit ADSF keeps a
value of 1 during A/D conversion, and is cleared to 0 automatically when conversion is complete.
The completion of conversion also sets bit IRRAD in interrupt request register 2 (IRR2) to 1. An
A/D conversion end interrupt is requested if bit IENAD in interrupt enable register 2 (IENR2) is
set to 1.
If the conversion time or input channel needs to be changed in the A/D mode register (AMR)
during A/D conversion, bit ADSF should first be cleared to 0, stopping the conversion operation,
in order to avoid malfunction.
12.3.2

Start of A/D Conversion by External Trigger Input

The A/D converter can be made to start A/D conversion by input of an external trigger signal.
External trigger input is enabled at pin ADTRG when bit IRQ4 in port mode register 2 for the I/O
port (PMR2) is set to 1, and bit TRGE in AMR is set to 1. Then when the input signal edge
designated in bit IEG4 of the IRQ edge select register (IEGR) is detected at pin ADTRG, bit
ADSF in ADSR will be set to 1, starting A/D conversion.
Figure 12.2 shows the timing.
ø
Pin ADTRG
(when bit
IEG4 = 0)
ADSF
12.4

Interrupts

When A/D conversion ends (ADSF changes from 1 to 0), bit IRRAD in interrupt request
register 2 (IRR2) is set to 1.
Figure 12.2 External Trigger Input Timing
A/D conversion
287

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8/3635H8/3636

Table of Contents