Salicru CV30 User Manual page 91

Inverter controlvit
Table of Contents

Advertisement

Checking part
Terminals seat
Filter capacitors
Resistors
Transformers and
reactors
Electromagnetism
contactors and relays
Control
PCB and plugs
circuit
Fault Tracking
Checking item
Ensure that there is no
damage
Ensure that there is no
weeping, color-changing,
cracking and chassis
expansion.
Ensure the safety valve is in
the right place.
If necessary, measure the
static capacity.
Ensure whether there is
replacement and splitting
caused by overheating.
Ensure that it is not offline.
Ensure there is no abnormal
vibration, noise and smelling,
Ensure whether there is no
vibration noise in the
workrooms.
Ensure the contactor is good
enough.
Ensure there are no loose
screws and contactors.
Ensure there is no smelling
and color-changing.
Ensure there are no cracks,
damage distortion and rust.
Ensure there is no weeping
and distortion to the
capacitors.
Checking method
Visual examination
NA
Visual examination
NA
Estimate the usage
time according to
the maintenance or
NA
measure the static
capacity.
The static capacity
Measure the
is above or equal to
capacity by
the original value
instruments.
*0.85.
Smelling and visual
NA
examination
Visual examination
The resistors are in
or measure with
±10% of the
multimeter
standard value.
Hearing, smelling
and visual
NA
examination
Hearing
NA
Visual examination
NA
Fasten up
NA
Smelling and visual
NA
examination
Visual examination
NA
Visual examination or
estimate the usage
time according to the
NA
maintenance
information
Criterion
91 - 140

Hide quick links:

Advertisement

Table of Contents
loading