Salicru CV30 User Manual page 39

Inverter controlvit
Table of Contents

Advertisement

Function
Name
code
Restart after
P01.21
power off
Waiting time of
P01.22
restart after
power off
P01.23 Start delay time
Delay time of
P01.24
the stopping
speed
0Hz output
P01.25
selection
Function Parameters
Detailed instruction of parameters
Setting range: 0.0~3600.0s (valid when P01.19=2)
This function can enable the inverter start or not after the
power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the inverter will run
automatically after waiting for the time defined by P01.22.
The function determines the waiting time before the
automatic running of the inverter when powering off and then
powering on.
Setting range: 0.0~3600.0s (valid when P01.21=1)
The function determines the brake release after the running
command is given, and the inverter is in a stand-by state and
wait for the delay time set by P01.23
Setting range: 0.0~60.0s
Setting range: 0.0~100.0s
Select the 0Hz output of the inverter.
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
P02 Group Motor
Default
Modify
value
0
1.0s
0.0s
0.0s
0
39 - 140