Function
Name
code
Integral ratio of
P08.43
the keypad
potentiometer
UP/DOWN
P08.44
terminals
control setting
UP terminal
P08.45
frequency
changing ratio
DOWN
P08.46
terminal
frequency
70 - 140
Detailed instruction of parameters
2: Only analog potentiometer adjustments are valid
3: Neither ∧/∨ keys nor analog potentiometer adjustments
are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when multi-step speed has the
priority
LED hundreds: action selection during stopping
0: Setting is valid
1:Valid during running, cleared after stopping
2: Valid during running, cleared after receiving the stop
command
LED thousands: ∧/∨ keys and analog potentiometer
integral function
0: The Integral function is valid
1: The Integral function is invalid
0.01~10.00s
0x00~0x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting invalid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
2: When the multi-step are priority, it is invalid to the
multi-step
LED hundreds: action selection when stop
0: Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after receiving the stop
commands
0.01~50.00 Hz/s
0.01~50.00 Hz/s
Default
Modify
value
0.10s
0x000
0.50
Hz/s
0.50
Hz/s
Fault Tracking