Salicru CV30 User Manual page 43

Inverter controlvit
Table of Contents

Advertisement

Function
Name
code
Keypad setting
P03.12
torque
Torque reference
P03.13
filter time
Setting source
of forward
rotation
P03.14
upper-limit
frequency in
torque control
Setting source
of reverse
rotation
P03.15
upper-limit
frequency in
torque control
Torque control
forward
rotation
P03.16
upper-limit
frequency
keypad defined
value
Torque control
reverse
rotation
P03.17
upper-limit
frequency
keypad defined
value
Upper-limit
P03.18
setting of
Function Parameters
Detailed instruction of parameters
4: Analog AI3 setting torque
5: Pulse frequency HDI setting torque
6: Multi-step torque setting
7: MODBUS communication setting torque
8~10: Reserved
Note: Setting mode 2~7, 100% corresponds to 3 times of the
motor rated current
Setting range: -300.0%~300.0% (motor rated current)
0.000~10.000s
0: keypad setting upper-limit frequency (P03.16 sets P03.14,
P03.17 sets P03.15)
1: Analog AI1 setting upper-limit frequency
2: Analog AI2 setting upper-limit frequency
3: Analog AI3 setting upper-limit frequency
4: Pulse frequency HDI setting upper-limit frequency
5: Multi-step setting upper-limit frequency
6: MODBUS communication setting upper-limit frequency
7~9: Reserved
Note: setting method 1~9, 100% corresponds to the
maximum frequency
This function is used to set the upper limit of the frequency.
P03.16 sets the value of P03.14; P03.17 sets the value of
P03.15.
Setting range:0.00 Hz~P00.03 (the Max. output frequency)
This function code is used to select the electromotion and
braking torque upper-limit setting source selection.
Default
Modify
value
50.0%
0.100s
0
0
50.00
Hz
50.00
Hz
0
43 - 140