Salicru CV30 User Manual page 52

Inverter controlvit
Table of Contents

Advertisement

Function
Name
code
S1 terminal
P05.14
switching on
delay time
S1 terminal
P05.15
switching off
delay time
S2 terminal
P05.16
switching on
delay time
52 - 140
Detailed instruction of parameters
Sln
FWD
ON
OFF→ON
ON
ON
OFF
ON→OFF
Note: for the 2-wire running mode, when FWD/REV terminal is
valid, the inverter stops because of the stopping command from
other sources, even the control terminal FWD/REV keeps valid;
the inverter won't work when the stopping command is canceled.
Only when FWD/REV is relaunched, the inverter can start again.
For example, the valid STOP/RST stop when PLC signal cycles
stop, fixed-length stop and terminal control (see P07.04).
The function code defines the corresponding delay time of
electrical level of the programmable terminals from switching
on to switching off.
REV
Direction
ON
Forward
OFF
Reverse
Forward
OFF→ON
Reverse
Decelerate
to stop
Default
Modify
value
0.000s
0.000s
0.000s
Fault Tracking