Salicru CV30 User Manual page 115

Inverter controlvit
Table of Contents

Advertisement

Function
instruction
SW 2 of the inverter
Fault code of the
inverter
Identifying code of
the inverter
Operation
frequency
Setting frequency
Bus voltage
Output voltage
Output current
Operation speed
Output power
Output torque
Close loop setting
Close loop
feedback
PID setting
PID feedback
Input IO
Input IO
AI 1
AI 2
AI 3
AI 4
Read high speed
pulse 1 input
Communication protocol
Address
definition
Bit0: =0:bus voltage is not established =1:bus
voltage is established
Bi1~2: =00:motor 1
Bit3: =0:asynchronous motor
2101H
Bit4: =0:pre-alarm without overload
=1:overload pre-alarm
Bit5~ Bit6: =00: keypad control
2102H
See the fault type instruction
2103H
CV30-----0x0106
3000H
Range: 0.00Hz~P00.03
3001H
Range: 0.00Hz~P00.03
3002H
Range: 0~2000V
3003H
Range: 0~1200V
3004H
Range: 0.0~3000.0 A
3005H
Range: 0~65535 RPM
3006H
Range: -300.0~300.0%
3007H
Range: -250.0~250.0%
3008H
Range: -100.0%~100.0%
3009H
Range: -100.0%~100.0%
3008H
-100.0~100.0% (unit: 0.1%)
3009H
-100.0~100.0% (unit: 0.1%)
300AH
000~1FF
300BH
000~1FF
300CH
Range: 0.00~10.00V
300DH
Range: 0.00~10.00V
300EH
Range: 0.00~10.00V
300FH
Range: -10.00~10.00V
3010H
Range: 0.00~50.00kHz
Data meaning instruction
=01: terminal control
=10: communication control
R/W
characteristics
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
115 - 140