User's
P07.00
password
Function Parameters
Detailed instruction of parameters
14: MODBUS communication set value 1
15: MODBUS communication set value 2
16~21: Reserved
22: Torque current (corresponds to 3 times of the rated
current of the motor)
23: Ramp reference frequency (with sign)
24~30: Reserved
These function codes define the relative relationship
between the output value and analog output. When the
output value exceeds the range of set maximum or minimum
output, it will count according to the low-limit or upper-limit
output.
When the analog output is current output, 1mA equals to
0.5V.
In different cases, the corresponding analog output of 100%
of the output value is different. Please refer to each
application for detailed information.
Setting range of P06.17: -100.0%~ P06.19
Setting range of P06.18: 0.00V~10.00V
Setting range of P06.19: P06.17~100.0%
Setting range of P06.20: 0.00V~10.00V
Setting range of P06.21: 0.000s~10.000s
Setting range of P06.22: -100.0%~ P06.24
Setting range of P06.23: 0.00V~10.00V
Setting range of P06.24: P06.22~100.0%
Setting range of P06.25: 0.00V~10.00V
Setting range of P06.26: 0.000s~10.000s
P07 Group Human-Machine Interface
0~65535
The password protection will be valid when setting any
non-zero number.
Default
Modify
value
0.0%
0.00V
100.0%
10.00V
0.000s
0.0%
0.00V
100.0%
10.00V
0.000s
0