Salicru CV30 User Manual page 17

Inverter controlvit
Table of Contents

Advertisement

3.2.2 Terminals figure of main circuit
Figure 3-5 3PH terminals of main circuit (220V≤0.75kW, and 400V≤2.2kW)
Figure 3-6 3PH terminals of main circuit (400V≥4 kW and 220V≥1.5kW)
Terminal
L, N
R, S, T
PB, (+)
(+), (-)
U, V, W
PE
Note:
 Do not use asymmetrically constructed motor cables. If there is a symmetrically constructed
grounding conductor in the motor cable in addition to the conductive shield, connect the
grounding conductor to the grounding terminal at the inverter and motor ends.
 Route the motor cable, input power cable and control cables separately.
Installation Guidelines
Figure 3-4 1PH terminals of main circuit (single-phase)
Single-phase AC input terminals which are generally connected with
the power supply.
Three-phase AC input terminals which are generally connected with
the power supply.
External dynamic braking resistor terminal
Input terminal for DC bus
Three-phase AC output terminals which are generally connected to
the motor.
Protective grounding terminal
Function
17 - 140