Salicru CV30 User Manual page 114

Inverter controlvit
Table of Contents

Advertisement

Function
instruction
SW 1 of the inverter
114 - 140
Address
definition
Torque setting value (-3000~3000), 1000
2004H
corresponds to the 100.0% of the rated current
of the motor
The upper limit frequency setting during forward
2005H
rotation (0~Fmax) Unit: 0.01Hz
The upper limit frequency setting during reverse
2006H
rotation (0~Fmax) Unit: 0.01Hz
The upper limit torque of electromotion torque
2007H
(0~3000) 1000 corresponds to the 100.0% of the
rated current of the motor
The upper limit torque of braking torque
2008H
(0~3000) 1000 corresponds to the 100.0% of the
rated current of the motor
Special control command word
Bit0~1:=00:motor
Bit2:=1 torque control prohibit
=0: torque control prohibit invalid
2009H
Bit3: =1 power consumption clear
=0: no power consumption clear
Bit4: =1 pre-exciting =0: pre-exciting
prohibition
Bit5: =1 DC braking =0: DC braking prohibition
Virtual input terminal command , range:
200AH
0x000~0x1FF
Virtual input terminal command , range:
200BH
0x00~0x0F
Voltage setting value (special for V/F separation)
200CH
(0~1000, 1000 corresponds to the 100.0% of the
rated voltage of the motor)
AO output setting 1
200DH
(-1000~1000, 1000 corresponds to 100.0%)
AO output setting 2
200EH
(-1000~1000, 1000 corresponds to 100.0%)
0001H: forward running
0002H: reverse running
0003H: stop
2100H
0004H: fault
0005H: Power Off state
0006H: pre-exciting state
Data meaning instruction
R/W
characteristics
W/R
W/R
W/R
W/R
W/R
W/R
W/R
W/R
W/R
W/R
W/R
R
Communication protocol

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents