NEGATIVE DC connector set and terminal AC connector RS485 communications connector If anything is missing, contact your supplier in order to return this device and arrange for a new one, containing all of the listed items, to be delivered. SALICRU...
2. MECHANICAL INSTALLATION. 2.1. POSITIONING THE DEVICE If you are installing the optional ESM3T EQX energy meter, we recommend installing the inverter as near to the electrical connection as possible, in order to avoid extending the RS485 communications cable. Angle and spacing of the installation: Make sure the device is installed on a vertical surface and that the following minimum safety distances are maintained with regard to other elements, in order to ensure optimum ventilation: Dimension...
Page 6
Mounting process Material required Steps to follow: SALICRU...
3. ELECTRICAL INSTALLATION. 3.1. DC (DIRECT CURRENT) INSTALLATION Make sure the inverter’s isolator switch is in the OFF position. Make sure the protection systems in the junction box are activated and that there is no voltage in the cables you are going to handle.
Page 8
Max. input current per MPPT x no. of MPPTs 10 A x 2 12 A x 2 12,5 A x 2 Max. short-circuit current per MPPT (Isc PV) x no. of MPPTs 11 A x 2 13 A x 2 14 A x 2 SALICRU...
Page 9
Connect the cables to the inverter in accordance with the following connection diagrams: Connection process for facilities with solar parks of varying power (panels with different orientations and/or strings of different lengths): If the facility’s solar panels are not on the same level, i.e. they are exposed to different levels of radiation (whether due to the shape of the roof, differences in inclination, or different string lengths), the connection process must be carried out as follows: The devices allow for a maximum solar power imbalance of 40%-60%.
Make sure the protection systems in the junction box are activated and that there is no voltage in the cables you are going to handle. If you are installing the optional ESM3T EQX energy meter, we recommend installing the inverter as near to the electrical connection as possible, in order to avoid extending the RS485 communications cable. Material required: SALICRU...
Page 11
Connecting the network cables: Unscrew the AC connector (supplied) and prepare the cables coming from the junction box of the power supply: Pass the cables through the screw cap, crown and rubber seal, as shown below. To optimise the connection, we recommend crimping the terminals at the ends of the cables.
4P 25 A 30 mA Class A Type II, 40 kA 400 V TNC 125 A gL EQX 10000-2T 3P 16 A Curve C 4P 25 A 30 mA Class A Type II, 40 kA 400 V TNC 125 A gL SALICRU...
Page 13
Example of a junction box with DC protections on the left and AC protections on the right. QUICK GUIDE EQUINOX - SOLAR INVERTERS...
Shut off the solar park power supply. Activate the protections in order to shut off the photovoltaic supply. Deactivate the inverter’s isolator switch and place it in the OFF position. The device will stop. When the internal capacitors of the DC bus are without voltage, the LCD screen will turn off. SALICRU...
5. OPERATION USING THE DISPLAY. 5.1. DISPLAY The buttons are operated by touch. Take care not to activate any functions accidentally. Button Symbol Function Exit the current mode. Go back to the previous menu. Access the Settings menu. Enter the chosen parameter. Confirm the value entered.
Page 17
Now you must set the time. The example below shows how to set the time to 16:45:00: Date/Time Date/Time Date/Time Date: 2025/03/09 Date: 2025/03/09 Date: 2025/03/09 Time: 12:00:00 Time: 16:00:00 Time: 16:00:00 Date/Time Date/Time Fecha/Hora Date: 2025/03/09 Date: 2025/03/09 Fecha: 09/03/2025 Time: 16:45:00 Time: 16:45:00 Hora: 16:45:00...
Page 18
I n p u t p a s s w o r d : 2 0 1 0 2 0 1 2 If the password entered is correct, the sub-menu will appear automatically. If the password is incorrect, the words “Error, again!” will appear.Press ENT to try again. SALICRU...
EThe inverter interrupts generation due to a serious error caused by one of the following: - Low isolation impedance. Error - High leakage current. - DC injected into the mains. - Overcurrent in the DC input. - DC polarity inverted. SALICRU...
5.4. FAULT CODES Fault codes are shown in the bottom right of the LCD screen. The table below details all of the fault codes that the inverter may display: Code Fault Description A001 PV UV Solar panel input voltage low. A002 Bus UV Inverter DC bus voltage low.
6.1. DOWNLOADING AND INSTALLING THE APP ON YOUR SMARTPHONE Download the EQX-sun app from either the Play Store (Android) or App Store (iOS), depending on your smartphone’s operating system. After you have downloaded the app, follow the instructions it will give you. SALICRU...
Page 23
: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................QUICK GUIDE EQUINOX - SOLAR INVERTERS...
Page 24
REF. EN106E01 REV. E CODE 401* Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 sst@salicru.com SALICRU.COM Information about our technical service and support network (T.S.S.), sales network and warranty is available on our website: www.salicru.com...