Function
Name
code
Polarity
selection of
P06.05
output
terminals
Y1 open delay
P06.06
time
Y1 off delay
P06.07
time
RO1 switching
P06.10
on delay time
RO1 switching
P06.11
off delay time
RO2 switching
P06.12
on delay time
RO2 switching
P06.13
off delay time
AO1 output
P06.14
selection
AO2 output
P06.15
selection
56 - 140
Detailed instruction of parameters
27~30: Reserved
The function code is used to set the pole of the output terminal.
When the current bit is set to 0, output terminal is positive.
When the current bit is set to 1, output terminal is negative.
BIT3
BIT2
RO2
RO1
Setting range: 0~F
The setting range: 0.000~50.000s
The setting range: 0.000~50.000s
The function code defines the corresponding delay time of
the electrical level change during the programmable terminal
switching on and off.
The setting range: 0.000~50.000s
0: Running frequency
1: Setting frequency
2: Ramp reference frequency
3: Running rotation speed
4: Output current (relative to twice the inverter rated current)
5: Output current (relative to twice the motor rated current)
6: Output voltage
7: Output power
8: Set torque value
9: Output torque
10: Analog AI1 input value
11: Analog AI2 input value
12: Analog AI3 input value
13: High speed pulse HDI input value
BIT1
BIT0
Reserved
Y1
Default
Modify
value
0
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0
0
Fault Tracking