Salicru CV30 User Manual page 75

Inverter controlvit
Table of Contents

Advertisement

Function
Name
code
Proportional
P09.14
gain at low
frequency (Kp)
PID command
P09.15
of ACC/DEC
time
PID output filter
P09.16
time
P10 Group
Simple PLC
P10.00
means
Simple PLC
P10.01
memory
Function Parameters
Detailed instruction of parameters
between the reference and the feedback unless it reaches the
internal integral limit. When the trend between the reference and
the feedback changes, it needs more time to offset the impact of
continuous working and the integration will change with the trend.
1: Stop integral adjustment when the frequency reaches
the upper and low limit. If the integration keeps stable, and
the trend between the reference and the feedback changes,
the integration will change with the trend quickly.
LED tens (P00.08 is 0)
0: Same with the setting direction; if the output of PID
adjustment is different from the current running direction, the
internal control will output 0 forcedly.
1: Opposite to the setting direction
LED hundreds (P00.08 is 0)
0: Limit to the maximum frequency
1: Limit to A frequency
LED thousands:
0: A+B frequency, buffer ACC/DEC is invalid for the main
reference A frequency source
1: A+B frequency, buffer ACC/DEC is valid for the main
reference A frequency source and the ACC/DEC is
determined by time set in P08.04
0.00~100.00
0.0~1000.0s
0.000~10.000s
Simple PLC and multi-step speed control
0: Stop after running once. The inverter has to be
commanded again after finishing a cycle.
1: Run at the final value after running once. After finish a
signal, the inverter will keep the running frequency and
direction of the last run.
2: Cycle running. The inverter will keep on running until
receiving a stop command and then, the system will stop.
0: Power loss without memory
1: Power loss memory. PLC record the running stage and
Default
Modify
value
1.00
0.0s
0.000s
0
0
75 - 140