Function
Name
code
jumping
frequency
range
Traverse boost
P08.17
time
Traverse
P08.18
declining time
Setting
P08.25
counting value
Given counting
P08.26
value
66 - 140
Detailed instruction of parameters
The traverse function means that the output frequency of the
inverter is fluctuated with the set frequency as its center. The
route of the running frequency is illustrated as below, of
which the traverse is set by P08.15 and when P08.15 is set
as 0, the traverse is 0 with no function.
Traverse range: The traverse running is limited by upper and
low frequency.
The traverse range relative to the center frequency: traverse
range AW=center frequency×traverse range P08.15.
Sudden jumping frequency=traverse range AW×sudden
jumping frequency range P08.16. When run at the traverse
frequency, the value which is relative to the sudden jumping
frequency.
The raising time of the traverse frequency: The time from the
lowest point to the highest one.
The declining time of the traverse frequency: The time from
the highest point to the lowest one.
The setting range of P08.15: 0.0~100.0%
(relative to the set frequency)
The setting range of P08.16: 0.0~50.0%
(relative to the traverse range)
The setting range of P08.17: 0.1~3600.0s
The setting range of P08.18: 0.1~3600.0s
The counter works by the input pulse signals of the HDI
terminals.
When the counter achieves a fixed number, the
multi-function output terminals will output the signal of "fixed
counting number arrival" and the counter go on working;
when the counter achieves a setting number, the
Default
Modify
value
5.0s
5.0s
0
0