41/THROTTLE VALVE BODY
Connecting the vacuum hand pump to the manifold absolute pressure sensor
29.8
at: 400 mbar (5.8 psi)
at: 450 mbar (6.53 psi)
at: 800 mbar (11.6 psi)
at: 850 mbar
(12.33 psi)
at: 900 mbar
(13.05 psi)
at: 950 mbar
(13.78 psi)
at: 1,000 mbar
(14.5 psi)
at: 1,050 mbar
(15.23 psi)
Manifold absolute pressure sensor cylinder 2, voltage "PM2AD"
at: 350 mbar (5.08 psi)
at: 400 mbar (5.8 psi)
at: 450 mbar (6.53 psi)
at: 800 mbar (11.6 psi)
at: 850 mbar
(12.33 psi)
at: 900 mbar
(13.05 psi)
at: 950 mbar
(13.78 psi)
at: 1,000 mbar
(14.5 psi)
at: 1,050 mbar
(15.23 psi)
–
Remove the filter box bottom. (
Connecting to the manifold absolute pressure sensor cylinder 1:
–
Pull off vacuum hose
–
Connect the vacuum hand pump to the vacuum hose of the manifold absolute
pressure sensor cylinder 1.
600856-10
Connecting to the manifold absolute pressure sensor cylinder 2:
–
Pull off vacuum hose
–
Connect the vacuum hand pump to the vacuum hose of the manifold absolute
pressure sensor cylinder 2.
600856-11
1.77... 1.83 V
1.92... 1.98 V
2.97... 3.03 V
3.12... 3.18 V
3.27... 3.33 V
3.42... 3.48 V
3.57... 3.63 V
3.72... 3.78 V
1.62... 1.68 V
1.77... 1.83 V
1.92... 1.98 V
2.97... 3.03 V
3.12... 3.18 V
3.27... 3.33 V
3.42... 3.48 V
3.57... 3.63 V
3.72... 3.78 V
p. 67)
.
.
224