KTM 1190 RC8 R EU/UK 2009 Repair Manual page 268

Hide thumbs Also See for 1190 RC8 R EU/UK 2009:
Table of Contents

Advertisement

ENGINE CONTROL TROUBLE CODE
Engine coolant temperature sensor cylinder 1 - the signal wire has a short circuit to ground (terminal 31)
Condition
The ignition is off.
The EFI control unit is disconnected. (
The break out box is connected to the wiring harness.
Engine coolant temperature sensor for cylinder 1 is disconnected. (
Engine coolant temperature sensor cylinder 1 - check the signal wire for a short circuit to ground (terminal 31)
Measure the resistance between the specified points.
Break Out Box AO pin 9 – Measuring point Ground (−)
Resistance
»
If the specifications have not been met:
Check the cable from EFI control unit connector AO (
ground (terminal 31).
»
If the specifications have been met:
Check the next possible cause:
Engine coolant temperature sensor cylinder 1 - the signal wire has a short circuit to sensor ground (
Engine coolant temperature sensor cylinder 1 - the signal wire has a short circuit to sensor ground
Resistance at: 40 °C (104 °F)
Resistance at: 50 °C (122 °F)
Resistance at: 60 °C (140 °F)
Resistance at: 70 °C (158 °F)
Resistance at: 80 °C (176 °F)
Resistance at: 90 °C (194 °F)
Resistance at: 100 °C (212 °F)
Resistance at: 110 °C (230 °F)
Resistance at: 120 °C (248 °F)
»
If the specifications have not been met:
Change the engine coolant temperature sensor cylinder 1.
»
If the specifications have been met:
Check the next possible cause:
Engine coolant temperature sensor cylinder 1 - the signal wire has a short cir-
cuit to ground (terminal 31) (
p. 227)
600850-11
Condition
The ignition is off.
The EFI control unit is disconnected. (
The break out box is connected to the wiring harness.
Engine coolant temperature sensor for cylinder 1 is disconnected. (
Engine coolant temperature sensor cylinder 1 - check the signal wire for a short circuit to
sensor ground
Measure the resistance between the specified points.
Break Out Box AO pin 9 – Break Out Box AO pin 7
Resistance
»
If the specifications have not been met:
600850-11
1.04... 1.27 kΩ
730... 892 Ω
526... 642 Ω
385... 471 Ω
286... 350 Ω
216... 264 Ω
165... 202 Ω
128... 156 Ω
100... 122 Ω
p. 266)
p. 198)
400658-10
∞ Ω
p. 392) pin 9 to connector AX (
p. 227)
∞ Ω
p. 395) pin 2 for a short circuit to
p. 266)
p. 198)
266

Advertisement

Table of Contents
loading

This manual is also suitable for:

1190 rc8 r aus 20091190 rc8 r jp 2009

Table of Contents