Maintenance; Important Safety Information - SPX FLOW Universal TS Series Instruction Manual

Rotary positive displacement twin screw pump
Table of Contents

Advertisement

Waukesha Cherry-Burrell Brand Universal TS Series

Maintenance

Important Safety
Information
06/2017
DANGER
The pump contains internal moving parts. DO NOT put hands or
fingers into the pump body ports or drive area at any time during
operation. To avoid serious injury, DO NOT install, clean, service,
or repair the pump unless all power is off and locked out and the
pump is de-pressurized.
WARNING
The pump components and piping may contain sharp edges.
Handle the screws carefully because edges may be sharp. Wear
gloves while installing and servicing the pump to help avoid
injuries from these hazards.
WARNING
Never touch the gear case during operation. The surface
temperature of the gear box can get above 160°F (71°C) when
running at 1000-3500 RPM.
CAUTION
Maintenance should be performed only by trained personnel. See
"Qualification Guidelines for Operating Staff" on page 12.
CAUTION
Make sure to keep the work area clear of machine parts, tools,
product lines, foreign materials, and power cables to avoid
potential hazards.
CAUTION
Make sure appropriate lighting is available: at least 1000 lux,
independent of daylight and weather conditions.
CAUTION
Before carrying out any maintenance and repair work on cold
components, ensure that the machine parts in question are
sufficiently heated. The contact temperature of accessible
machine parts must not be lower than those in the EN ISO
13732-1.
Before detaching port connections to the pump:
Close the suction and discharge valves.
Drain the pump and clean or rinse, if necessary.
Disconnect or shut off the electrical supply and lock out all
power.
95-03141