Operation
Starting the Pump
Stopping the Pump
Page 24
Waukesha Cherry-Burrell Brand Universal TS Series
WARNING
Keep a safe distance (1.6 ft/.5 m) away from the pump during
startup.
CAUTION
The motor must be installed by qualified personnel, e.g., a
licensed electrician.
CAUTION
In order to avoid temperature shock after the introduction of hot
product, stop the pump prior to, or immediately after filling with
hot product. Once the hot product has filled the pumphead, allow
15 minutes for the pump fluid components to thermally expand,
then re-start the pump.
1. Start the pump drive. Where possible, start at a slow speed
or jog.
2. For sanitary applications, sanitize the pump per customer
requirements before putting the pump into service.
3. Check to make sure that the liquid is reaching the pump. If
pumping does not begin and stabilize, check "Troubleshoot-
ing" on page 89.
WARNING
Keep a safe distance (1.6 ft/.5 m) away from the pump during
shutdown.
CAUTION
The motor must be installed by qualified personnel, e.g., a
licensed electrician.
1. Shut off the power to the pump drive.
2. Shut off the supply and discharge lines.
95-03141