Extension D/A Converter Module - Mitsubishi Electric NZ2GF2BN-60DA4 User Manual

Cc-link ie field network digital-analog converter module
Table of Contents

Advertisement

3.7.2

Extension D/A converter module

(1) Parameter area (address: 0200H to 02FFH)
Address
Type
Decimal
512
513
514
515
516
517
518
519
520
521
522
Extension
523
module 1
524
Module-based
parameter data
525
526
527
528
529
530
531
532
533
534
535 to 767
*1
This value is the value of factory default or the value of initialization by Parameter area initialization command (address:
1002H).
*2
This shows whether reading/writing data from/to a program is possible.
R: Readable
W: Writable
*3
This shows the items enabled by tuning on and off Initial data setting request flag (RY9).
(2) Monitor area (address: 0700H to 07FFH)
Type
1792
Extension module 1
Module-based monitor data
1793 to 2047
*1
Value at the time of turning off and on the module power supply or at the time of remote reset.
*2
This shows whether reading/writing data from/to a program is possible.
R: Readable
W: Writable
Hexadecimal
0200H
Extension module identification code
0201H
System area
0202H
D/A conversion enable/disable setting
0203H
Range setting
0204H
Analog output HOLD/CLEAR setting
0205H
Alert output setting
0206H
CH1 Alert output upper limit value
0207H
CH1 Alert output lower limit value
0208H
CH2 Alert output upper limit value
0209H
CH2 Alert output lower limit value
020AH
CH3 Alert output upper limit value
020BH
CH3 Alert output lower limit value
020CH
CH4 Alert output upper limit value
020DH
CH4 Alert output lower limit value
020EH
Scaling enable/disable setting
020FH
CH1 Scaling lower limit value
0210H
CH1 Scaling upper limit value
0211H
CH2 Scaling lower limit value
0212H
CH2 Scaling upper limit value
0213H
CH3 Scaling lower limit value
0214H
CH3 Scaling upper limit value
0215H
CH4 Scaling lower limit value
0216H
CH4 Scaling upper limit value
0217H to
System area
02FFH
Address
Decimal
Hexadecimal
0700H
0701H to 07FFH
Description
Default value
0000H
000FH
0000H
0000H
000FH
0000H
0000H
0000H
0000H
0000H
0000H
0000H
0000H
000FH
0
0
0
0
0
0
0
0
Description
Extension module identification code
System area
CHAPTER 3 SPECIFICATIONS
Necessity of
*1
*2
Read/Write
*3
RY9
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
*1
*2
Default value
Read/Write
0
R
43
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz2ex2b-60da4

Table of Contents