8.2

Drive Mode Switch

The D/A converter module operates in the following modes: normal mode, trigger output mode, and synchronous
communication mode.
The following table lists the types of drive mode and their operation.
Type of drive mode
Normal mode
Trigger output mode
Synchronous communication mode
The drive mode can be selected by setting Mode switch (address: 0000H).
(1) Setting procedure
1.
Set "Method selection" to "Parameter write".
"CC IE Field Configuration" window  Select the main D/A converter module from "List of stations"
[CC IE Field Configuration]  [Online]  [Parameter Processing of Slave Station]
2.
In "Station parameter", set "Mode switch" to either "0: Normal output mode", "1: Trigger output
mode", or "9: Automatical judgment mode".
The following table lists the setting value of "Mode switch" and the drive mode.
Setting value of "Mode switch"
"0: Normal conversion mode"
"1: Trigger output mode"
"9: Automatical judgment mode"
*1
The drive mode varies depending on the module of the master station as shown below.
Master station
Master/local module
(CC-Link IE Field Network synchronous communication function not
supported)
Master/local module
(CC-Link IE Field Network synchronous communication function supported)
Simple motion module
*2
For how to set the master station, refer to the MELSEC iQ-R Inter-Module Synchronization Function Reference Manual.
3.
Click
D/A conversion is performed based on the internal clock of the main D/A converter module.
D/A conversion is performed at the time of turning on Trigger out request (RY19, RY29) from off.
D/A conversion is performed with a synchronization period of the master station that supports the CC-Link IE Field
Network synchronous communication function.
The D/A converter module operates in normal mode.
The D/A converter module operates in trigger output mode.
The drive mode is automatically set according to the type of the module that operates as the
master station of the D/A converter module.
First five digits of the serial number
are 15091 or earlier.
First five digits of the serial number
are 15092 or later.
button to write the parameters to the D/A converter module.
Operation
Drive mode
*1
*2
Setting of the master station
Setting the CC-Link IE Field Network
synchronous communication function
to be disabled
Setting the CC-Link IE Field Network
synchronous communication function
to be enabled
CHAPTER 8 FUNCTIONS
Drive mode when "Mode switch" is
set to "9: Automatical judgment
mode"
Normal mode
Normal mode
Synchronous communication mode
Normal mode
Synchronous communication mode