(2) Programming conditions
Here is the programming conditions:
• D/A conversion in CH1 and CH2 of the main D/A converter module is enabled and the written digital values
are output in analog. Scaling conversion is performed in CH1 and alert output is performed in CH2.
• D/A conversion in CH1 to CH4 of the extension D/A converter module is enabled and the written digital
values are output in analog. Scaling conversion is performed in CH1 and CH3 and alert output is performed
in CH2 and CH4.
(3) Initial settings
(a) Station parameter
Cyclic data update watch time setting
For the parameters other than the above, use the initial value.
(b) Basic module parameter
D/A conversion enable/disable setting
Analog HOLD/CLEAR setting
Alert output function
Scaling function
For the parameters other than the above, use the initial value.
(c) Ext. module 1_Module parameter
Ext. module 1_D/A conversion enable/disable setting
Ext. module 1_Analog output HOLD/CLEAR setting
Ext. module 1_Alert output function
Ext. module 1_Scaling function
For the parameters other than the above, use the initial value.
Setting item
Setting item
CH1 D/A conversion enable/disable setting
CH2 D/A conversion enable/disable setting
CH1 Analog output HOLD/CLEAR setting
CH2 Alert output setting
CH2 Alert output upper limit value
CH2 Alert output lower limit value
CH1 Scaling enable/disable setting
CH1 Scaling upper limit value
CH1 Scaling lower limit value
Setting item
Ext. module 1_CH1 D/A conversion enable/disable setting
Ext. module 1_CH2 D/A conversion enable/disable setting
Ext. module 1_CH3 D/A conversion enable/disable setting
Ext. module 1_CH4 D/A conversion enable/disable setting
Ext. module 1_CH1 Analog output HOLD/CLEAR setting
Ext. module 1_CH3 Analog output HOLD/CLEAR setting
Ext. module 1_CH2 Alert output setting
Ext. module 1_CH2 Alert output upper limit value
Ext. module 1_CH2 Alert output lower limit value
Ext. module 1_CH4 Alert output setting
Ext. module 1_CH4 Alert output upper limit value
Ext. module 1_CH4 Alert output lower limit value
Ext. module 1_CH1 Scaling enable/disable setting
Ext. module 1_CH1 Scaling upper limit value
Ext. module 1_CH1 Scaling lower limit value
Ext. module 1_CH3 Scaling enable/disable setting
Ext. module 1_CH3 Scaling upper limit value
Ext. module 1_CH3 Scaling lower limit value
CHAPTER 9 PROGRAMMING
Setting value
5
Setting value
0: Enable
0: Enable
1: HOLD
0: Enable
10000
3000
0: Enable
32000
0
Setting value
0: Enable
0: Enable
0: Enable
0: Enable
1: HOLD
1: HOLD
0: Enable
10000
3000
0: Enable
10000
3000
0: Enable
32000
0
0: Enable
32000
0
139
9