Modules
Entrance Telephone Interface
Interfaces
3.11.1
Model: S30817-K930-A300 - TFE
Without amplifier, for installation of the following models:
EGUCOM (Ackermann, Emmerich);
●
Grothe,Telegärtner
●
HDL - Brazil (models: F3A, F4A, F5A);
●
Follow the diagram on Figure 3-39 for installing HDL models for Brazil
Figure 3-39
TFE Interface Overview - S30817-K930-A300
Additional components include: R1 (1.2 k Ω / 0.25W / 5%) and R2 (33Ω / 0.25W / 5%) resistors,
and C1 capacitor (1.0 μ F / 250 Vac / Non-polarized). The connection to the PABX is made with
two wires (a1 / b1) while the connection to the Entrance Telephone interface is made with four
wires (a2 / b2, KL1, KL2).
3.11.2
Model: S30122-k7696-F313 - TFE
With amplifier, for installation of the following models
Telekom Doorline M02;
●
Siedle;
●
Ritto;
●
3-63
A31003-K1160-S100-03-7620