Table 3-22 Tme1 Module, Dip Switch 1 - Siemens HiPath 1100 Service Manual

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

By changing the positions of the DIP switches the following settings can be configured:
DIP Switch 1 (S1)
It allows you to clean the Flash memory, select the Baud Rate and execute an auto-test.
Switch Proce
dure
1
FE
Delete Flash memory
Extended autotest
2
EST
(E1 CAS access)
2
EST
3
BR1
4
BR2
5
BR3
6
RES
7
RES
8
RES
Table 3-22
TME1 Module, DIP Switch 1
If an error occurs during software installation, clear the Flash memory and reinstall
the software. Follow these instructions:
Turn the PABX off
Set Switch 1 (FE) to ON
Turn the PABX on again
Wait for F and E to show on the display
Turn the PABX off
Set switch 1 (FE) to OFF again
Turn on the PABX
A31003-K1160-S100-03-7620
Service Manual
Meaning
ON - Deletes Flash memory when the PABX is turned
on
OFF - System will work as usual (default).
ON - Activates autotest (E1 CAS access)
OFF - Skips autotest (default1 ) (E1 CAS access).
For future applications (S2M access)
(3) OFF, (4) OFF and (5) OFF: 9600 bps
Baud rate
(3) OFF, (4) OFF and (5) ON: 19200 bps
configuration
(3) OFF, (4) ON and (5) OFF: 38400 bps
(3) OFF, (4) ON and (5) ON: 57600 bps (default)
Possible Settings
For future applications
Modules
Expansion Modules (EB)
3-38