Protection Of External Lines And Extensions; Figure 4-38 Diagram Of Power Supply Configuration For The Hipath 1150/1190/1190R Sys - Siemens HiPath 1100 Service Manual

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Recommendations concerning the Power Supply and Protection of the System
Protective Ground Connection
Danger
!
The HiPath 1150/1190/1190R power supplies must be protected by an earth ground
in a separate safety ground conductor (PE - green/yellow) (TN-S system, minimum
section = 2.5 mm
Any additional servicing of low voltage networks (100 - 240 V AC) must be done by
qualified technical personnel only.
Do not use as a grounding point:
- Central heating systems;
- Sewer systems;
- Ground wire for antennae systems.
Failure to comply with these recommendations may lead to hazardous conditions.
Example of a Power Supply Configuration for the HiPath 1150/1190/1190R Systems
L1 N PE
127 Vac
Figure 4-38
Diagram of Power Supply Configuration for the HiPath 1150/1190/1190R
Systems
4.13.1

Protection of External Lines and Extensions

The primary protection of external lines and extensions must be provided by grounding the
system through a separate cable (minimum section = 2.5 mm
protection of the telephone system. The secondary protection of external lines and extensions
is between wires A and B.
For primary protection for a distribution box that is external to the PABX use a MPT250 shield
with two PTCs (A and B wires) for overcurrent protection along with a gas capsule connected
to the ground wire through a separate cable that is independent of the cable used for grounding
the power supply.
A31003-K1160-S100-03-7620
Service Manual
2
) as shown in Figure 4-38.
HiPath 1150/1190/1190R
2
) set up exclusively for the
Installation
4-53