Installing Modules; On The Hipath 1120; On The Hipath 1150 - Siemens HiPath 1100 Service Manual

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

4.7.2

Installing Modules

4.7.2.1

On the HiPath 1120

Installation Procedures
Step
1.
Turn off the power supply.
2.
Remove the system's cover
3.
Insert the module into one of the slots shown in Figure 4-16.
4.
Connect the module to the MB using the flat cable on the top slot.
In the CND version, the EB module and the motherboard must be connected using
a power/connection cable.
5.
To install an ADSL or MOH module on the bottom slot lift the top slot and use the pin
connector to make the connection.
For all other modules use flat cable.
6.
Connect to modules MDF connectors (see Figure 4-32).
7.
Reassemble the entire set.
8.
"Performing a Visual Inspection" on page 4-59.
9.
Turn on the power supply.
10.
Configure the required data (see "Operation" on page 6-1).
4.7.2.2

On the HiPath 1150

Installation Procedures
Step
1.
Remove the power supply.
2.
Remove the backplane.
3.
Insert the module into one of the slots shown in Figure 4-18.
4.
Connect to modules MDF connectors (see Figure 4-34).
5.
Reassemble the entire set.
6.
"Performing a Visual Inspection" on page 4-59.
7.
Turn on the power supply.
A31003-K1160-S100-03-7620
Service Manual
Installation of Expansion and Option Modules
Procedure
Procedure
Installation
4-23