Installation
Installation of Expansion and Option Modules
Step
8.
Configure the required data (see "Operation" on page 6-1).
4.7.2.3

On the HiPath 1190/1190R

Installation Procedures
Step
1.
Turn off the power supply.
2.
Remove the system's front cover.
3.
Remove the system's back cover.
4.
Move the module's latch as shown in Figure 4-12.
5.
Insert the module into one of the slots shown in Table 4-2.
6.
Move the module's latch back to secure module.
7.
Connect the Main Distribution Frame cables as follows: For modules allocated to the
system's bottom slots (slots 1 to 10) use the bottom opening (see Figure 4-10). For
modules allocated to the system's top slots (slots 11 to 20) route the cables through
the top anchors (see Figure 4-11).
8.
Connect to the appropriate module connectors (see "Expansion Modules (EB)" on
page 3-19).
9.
Attach cables to anchors using plastic brackets.
10.
"Performing a Visual Inspection" on page 4-59.
11.
Reassemble the entire set.
12.
Turn on the power supply.
13.
Configure the required data (see "Operation" on page 6-1).
4.7.3

Installing a TME1 Module

Warning
!
Remember to set the DIP switches (see "TME1 Module" on page 3-33).