External Line Settings - Siemens HiPath 1100 Service Manual

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Configuring the system specifically for the client
Comments about the System's Programming Codes
Attendant Console (150)
This streamlines the flow of calls to one console equipped with a system telephone with a
display.
The Attendant Console does not receive "Direct message to the speakerphone" and
it cannot belong to any associated Group.
Carrier Dialing Mode Field: LCR or ACS (225)
This allows the user to change carrier selection and use the best possible option to originate
external calls.
ACS does not affect Emergency Numbers (040) when the user dials directly.
Warning Tone for Calls without LCR (092)
When the system is configured to use LCR, the HiPath 1100 can alert the user when an
external call is being places to a destination using a non-default carrier with higher rates for that
time of day. This may be due to the unavailability of an external line for LCR (Least Cost
Routing).
When using a standard telephone, a warning tone indicates to the user that a different carrier
is completing the call at this time. When using a system telephone, the carrier's name will show
on the display.
This feature works only for ISDN lines and it must be provided under contract from
a carrier.
7.2.2

External line settings

Group of External Lines (156)
Allows you to configure the access to an external line or a group of external lines using the
access code "0" or another than.
7-30
A31003-K1160-S100-03-7620
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1150Hipath 1120Hipath 1190

Table of Contents