Operation
HiPath 1100 Applications
CDR data are sent to the CDR application (Call Detail Report Manager) through TCP/IP
sockets. CDR displays CDR information on the PC screen and stores it in text file format. It also
makes CDR data available to a printer or a serial port, for example, for billing using the Call
Report software.
Events for Call Detail Records received from the system are sent through TAPI messages to a
TSP (TAPI Server Provider) using TCP/IP sockets, to provide data to other applications.
6.4.2

HiPath 1100 Manager

The HiPath 1100 Manager is an administration software designed for programming HiPath
1100 systems quickly and easily by means of a graphical interface without the need to know
programming codes.
The HiPath 1100 Manager can access the switch as follows:
Locally: Connecting a USB interface, an optiPoint 500 UP0/E interface, or a V.24 interface
Remotely: Through a LAN, provided there is a network PC connected to the HiPath 1100
via a serial or USB interface or an ADSL module
Offline Programming Mode: Allows you to view, edit and store a HiPath 1100 database on
a PC that is not currently connected to the PABX and later transfer it to it.
You can also update the HiPath 1100 software using the Software Update then store the
database with the system's settings.
If previous database versions have been saved (HiPath 1100 V5.1 and V5.2) and
you want to update the database to HiPath 1100 V6.0, you only need to restore the
*.bup file for the system to do the update automatically. Once the restore process is
completed, a popup message appears informing the user of the changes resulting
from the restore process.
When using remote administration over an ISDN digital line, where no traffic is
detected between the system and the remote programmer, the system can be
configured to terminate the connection after a specified period of time (1 to 60
minutes) or to maintain the connection indefinitely. The default timeout setting is 30
minutes.
Read the HiPath 1100 Manager Help file before proceeding with this operation.
6.4.3

HiPath 1100 ADSL Manager

The HiPath 1100 ADSL Manager is an administrative program for programming an ADSL
module.