Configuring the system specifically for the client
Comments about the System's Programming Codes
Number of Attempts for Activating the Sensor (053)
This setting specifies the number of call attempts (between 1 and 100) for the number specified
Number Dialed by Sensor Activation
in "
Activating the Sensor
An attempt is made after every call that was not answered (busy signal), or when the "Detect
DTMF Code" option (Code 70, Option 3) is enabled and no acknowledgment is received. When
this occurs, the call is disconnected and a new attempt is made.
Relay (175)
This setting specifies the operating mode for the relay:
"Switch" The relay can only be turned on from an extension by entering the proper feature
code (see Miscellaneous Functions - Relay in the User Manual).
"Monoflop": The relay is closed for a specified length of time. Alternatively, the relay can
also be opened before the set time by entering the proper feature code (see Miscellaneous
Functions - Relay in the User Manual).
"Invert": The current state of the Relay is reversed when the feature code for activating it is
selected at an extension.
"Music on Hold" The Relay can be used for activating external equipment connected for
playing messages/music.
"External signal" For an analog extension, a second ring can be enabled/disabled using the
relay.