Installation
System Cabling
4.15
System Cabling
Introduction
The connection between the extensions and the system is provided with cables as follows:
Color Group
Pair
1
2
1
3
4
5
6
7
2
8
9
10
Table 4-7
Color code for cables
The end of the cable that is attached to the system's Main Distribution Frame uses one of the
connector types shown in "Main Distribution Frame" on page 3-59.
4.16
Installing Telephone Terminals
A KS-type System Telephone has four wires (A, B, C, D), two used for voice (A, B), and two
for data (C, D).
An optiPoint System Telephone has four wires (A, B, C, D), two used for voice (A, B), and two
for data (C, D).
A Standard Telephone (DP/MF) has only two wires (A, B), both used for voice.
Standard Telephones (DP/MF) and optiPoint System Telephones must be connected
to the HiPath 1100 system using only wires A and B. Do not use wires (C,D).
4-56
A Wire
B Wire Color Group
br/az
az/br
br/lr
lr/br
br/vd
vd/br
br/ct
ct/br
br/cz
cz/br
vm/az
az/vm
vm/lr
lr/vm
vm/vd
vd/vm
vm/ct
ct/vm
vm/cz
cz/vm
Pair
11
12
3
13
14
15
4
16
A31003-K1160-S100-03-7620
A Wire
B Wire
pt/az
az/pt
pt/lr
lr/pt
pt/vd
vd/pt
pt/ct
ct/pt
pt/cz
cz/pt
am/az
az/am
Service Manual