7.11.6 40-WSS-CE Card-Level Indicators
Table 7-35
Band ID
B42.5
B46.5
B50.5
B54.4
B58.6
7.11.6 40-WSS-CE Card-Level Indicators
The 40-WSS-CE card has three card-level LED indicators, described in
Table 7-36
Card-Level Indicators
Red FAIL LED
Cisco ONS 15454 DWDM Reference Manual, R8.5
7-62
40-WSS-CE Channel Plan (continued)
Channel Label Frequency (GHz)
42.5
194.35
43.3
194.25
44.1
194.15
44.9
194.05
45.7
193.95
46.5
193.85
47.3
193.75
48.1
193.65
48.9
193.55
49.7
193.45
50.5
193.35
51.3
193.25
52.1
193.15
52.9
193.05
53.7
192.95
54.4
192.85
55.3
192.75
56.1
192.65
56.9
192.55
57.8
192.45
58.6
192.35
59.4
192.25
60.2
192.15
61.0
192.05
61.8
191.95
40-WSS-CE Card-Level Indicators
Description
The red FAIL LED indicates that the card's processor is not ready or that an
internal hardware failure occurred. Replace the card if the red FAIL LED
persists.
Chapter 7
Reconfigurable Optical Add/Drop Cards
Wavelength (nm)
1542.54
1543.33
1544.13
1544.92
1545.72
1546.52
1547.32
1548.11
1548.91
1549.72
1550.52
1551.32
1552.12
1552.93
1553.73
1554.54
1555.34
1556.15
1556.96
1557.77
1558.58
1559.39
1560.20
1561.01
1561.83
Table
7-36.
78-18343-02