8.7.6 Client Interfaces

The MXP_2.5G_10E provides four intermediate- or short-range OC-48/STM-16 ports per card on the
client side. Both SR-1 or IR-1 optics can be supported and the ports use SFP connectors. The client
interfaces use four wavelengths in the 1310-nm, ITU 100-MHz-spaced, channel grid.
8.7.6.1 DWDM Interface
The MXP_2.5G_10E serves as an OTN multiplexer, transparently mapping four OC-48 channels
asynchronously to ODU1 into one 10-Gbps trunk. The DWDM trunk is tunable for transmission over
four wavelengths in the 1550-nm, ITU 100-GHz spaced channel grid.
You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E card in a
Caution
loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E card. Using
direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10E card.
8.7.7 Multiplexing Function
The muxponder is an integral part of the reconfigurable optical add/drop multiplexer (ROADM)
network. The key function of MXP_2.5G_10E is to multiplex 4 OC-48/STM16 signals onto one ITU-T
G.709 OTU2 optical signal (DWDM transmission). The multiplexing mechanism allows the signal to be
terminated at a far-end node by another MXP_2.5G_10E card.
Termination mode transparency on the muxponder is configured using OTUx and ODUx OH bytes. The
ITU-T G.709 specification defines OH byte formats that are used to configure, set, and monitor frame
alignment, FEC mode, section monitoring, tandem connection monitoring, and termination mode
transparency.
78-18343-02
MXP_2.5G_10E Block Diagram
DWDM
(trunk)
10GE
Optical
transceiver
Optical
SR-1
transceiver
or
Optical
IR-1
transceiver
Optical
SFP client
transceiver
Optical
transceiver
Onboard
Flash
memory
FEC/
Wrapper
E-FEC
Processor
(G.709 FEC)
Processor
RAM
Cisco ONS 15454 DWDM Reference Manual, R8.5
8.7.6 Client Interfaces
B
Serial bus
a
c
k
p
l
a
n
e
uP bus
8-31

Advertisement

Table of Contents
loading

Table of Contents