Table 7-41 Mmu Port Calibration; Table 7-42 Mmu Card-Level Indicators; Mmu Power Monitoring - Cisco ONS 15454 DWDM Reference Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 7
Reconfigurable Optical Add/Drop Cards
Figure 7-36
MMU Block Diagram
VPD2
75/25
COM TX
VPD3
COM RX

7.13.3 MMU Power Monitoring

Physical photodiodes P1 through P3 monitor the power for the MMU card. The returned power level
values are calibrated to the ports as shown in
been created by adding (by software computation) the relevant path insertion losses of the optical
splitters (stored in the module) to the real photodiode (P1 to P3) measurement.
Table 7-41
Photodiode
P1
P2
P3
VP1
VP2
VP3
7.13.4 MMU Card-Level Indicators
Table 7-42
Table 7-42
Card-Level Indicators
Red FAIL LED
78-18343-02
PD1
PD2
95/5
VPD1
PD3
MMU Port Calibration
CTC Type Name
1 (EXP-RX)
5 (EXP A-RX)
6 (EXP A-TX)
2 (EXP-TX)
4 (COM-TX)
3 (COM-RX)
describes the three card-level LED indicators on the MMU card.
MMU Card-Level Indicators
Description
The red FAIL LED indicates that the card's processor is not ready or that n
internal hardware failure occurred. Replace the card if the red FAIL LED
persists.
EXP RX
EXP A RX
95/5
EXP TX
EXP A TX
Table
7-41. VP1 to VP3 are virtual photodiodes that have
Calibrated to Port
EXP RX
EXP A RX
EXP A TX
EXP TX
COM TX
COM RX
Cisco ONS 15454 DWDM Reference Manual, R8.5
7.13.3 MMU Power Monitoring
Legend
LC PC II Connector
Optical splitter/coupler
Real photodiode
Virtual photodiode
7-71