Mux-C Card-Level Indicators - Cisco ONS 15454 DWDM Reference Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 7
Reconfigurable Optical Add/Drop Cards
Table 7-27
Band ID
B50.1
B54.1
B58.1

7.9.5 40-MUX-C Card-Level Indicators

The 40-MUX-C card has three card-level LED indicators, described in
Table 7-28
Card-Level Indicators
Red FAIL LED
Green ACT LED
Amber SF LED
7.9.6 40-MUX-C Port-Level Indicators
You can find the alarm status of the 40-MUX-C card ports using the LCD screen on the ONS 15454
fan-tray assembly. The screen displays the number and severity of alarms on a given port or slot. For the
procedure to view these counts, refer to "Manage Alarms" in the Cisco ONS 15454 DWDM Procedure
Guide.
78-18343-02
40-MUX-C Channel Plan (continued)
Channel Label Frequency (GHz)
50.1
193.4
50.9
193.3
51.7
193.2
52.5
193.1
53.3
193
54.1
192.9
54.9
192.8
55.7
192.7
56.5
192.6
57.3
192.5
58.1
192.4
58.9
192.3
59.7
192.2
60.6
192.1
61.4
192
40-MUX-C Card-Level Indicators
Description
The red FAIL LED indicates that the card's processor is not ready or that an
internal hardware failure occurred. Replace the card if the red FAIL LED
persists.
The green ACT LED indicates that the 40-MUX-C card is carrying traffic or
is traffic-ready.
The amber SF LED indicates a signal failure on one or more of the card's
ports. The amber SF LED also turns on when the transmit and receive fibers
are incorrectly connected. When the fibers are properly connected, the light
turns off.
7.9.5 40-MUX-C Card-Level Indicators
Wavelength
(nm)
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.36
1558.17
1558.98
1559.79
1560.61
1561.42
Table
7-28.
Cisco ONS 15454 DWDM Reference Manual, R8.5
7-49