Chapter 6
Optical Add/Drop Cards
Table 6-12
Band ID
Band 30.3 (A)
Band 34.2 (B)
Band 38.1 (C)
Band 42.1 (D)
Band 46.1 (E)
Band 50.1 (F)
Band 54.1 (G)
Band 58.1 (H)

6.5.2 Power Monitoring

Physical photodiodes P1 through P10 and virtual photodiodes V1 and V2 monitor the power for the
AD-4C-xx.x card. The returned power level values are calibrated to the ports as shown in
Table 6-13
Photodiode
P1–P4
P5–P8
P9
P10
V1
V2
For information on the associated TL1 AIDs for the optical power monitoring points, refer the "CTC
Port Numbers and TL1 Aids" section in Cisco ONS SONET TL1 Command Guide, Release 8.5.
6.5.3 AD-4C-xx.x Card-Level Indicators
The AD-4C-xx.x card has three card-level LED indicators, described in
Table 6-14
Card-Level Indicators
Red FAIL LED
78-18343-02
AD-4C-xx.x Channel Sets
Add/Drop Wavelengths
1530.3, 1531.2, 1531.9, 1532.6
1534.2, 1535.0, 1535.8, 1536.6
1538.1, 1538.9, 1539.7, 1540.5
1542.1, 1542.9, 1543.7, 1544.5
1546.1, 1546.9, 1547.7, 1548.5
1550.1, 1550.9, 1551.7, 1552.5
1554.1, 1554.9, 1555.7, 1556.5
1558.1, 1558.9, 1559.7, 1560.6
AD-4C-xx.x Port Calibration
CTC Type Name
ADD
DROP
IN EXP
OUT EXP
IN COM
OUT COM
AD-4C-xx.x Card-Level Indicators
Description
The red FAIL LED indicates that the card's processor is not ready or that
there is an internal hardware failure. Replace the card if the red FAIL LED
persists.
Calibrated to Port
COM TX
DROP TX
EXP RX
EXP TX
COM RX
COM TX
Table