2.4.2 External Alarms and Controls

Table 2-7
Card-Level LEDs
Green/Red PWR A LED The PWR A LED is green when a supply voltage within a specified range
Green/Red PWR B LED The PWR B LED is green when a supply voltage within a specified range has
Yellow INPUT LED
Yellow OUTPUT LED
Green RING LED
Green RING LED
2.4.2 External Alarms and Controls
The AIC-I card provides input/output alarm contact closures. You can define up to 12 external alarm
inputs and 4 external alarm inputs/outputs (user configurable). The physical connections are made using
the backplane wire-wrap pins or FMEC connections. See the
Panel" section on page 1-32
LEDs on the front panel of the AIC-I indicate the status of the alarm lines, one LED representing all of
the inputs and one LED representing all of the outputs. External alarms (input contacts) are typically
used for external sensors such as open doors, temperature sensors, flood sensors, and other
environmental conditions. External controls (output contacts) are typically used to drive visual or
audible devices such as bells and lights, but they can control other devices such as generators, heaters,
and fans.
You can program each of the twelve input alarm contacts separately. You can program each of the sixteen
input alarm contacts separately. Choices include:
You cannot assign the fan-tray abbreviation for the alarm; the abbreviation reflects the generic name of
the input contacts. The alarm condition remains raised until the external input stops driving the contact
or you provision the alarm input.
The output contacts can be provisioned to close on a trigger or to close manually. The trigger can be a
local alarm severity threshold, a remote alarm severity, or a virtual wire:
Cisco ONS 15454 DWDM Reference Manual, R8.5
2-12
AIC-I Card-Level Indicators (continued)
Description
has been sensed on supply input A. It is red when the input voltage on supply
input A is out of range.
been sensed on supply input B. It is red when the input voltage on supply
input B is out of range.
The INPUT LED is yellow when there is an alarm condition on at least one
of the alarm inputs.
The OUTPUT LED is yellow when there is an alarm condition on at least one
of the alarm outputs.
The RING LED on the local orderwire (LOW) side is flashing green when a
call is received on the LOW.
The RING LED on the express orderwire (EOW) side is flashing green when
a call is received on the EOW.
for information about increasing the number of input/output contacts.
Alarm on Closure or Alarm on Open
Alarm severity of any level (Critical, Major, Minor, Not Alarmed, Not Reported)
Service Affecting or Non-Service Affecting alarm-service level
63-character alarm description for CTC display in the alarm log
Local NE alarm severity: A hierarchy of Not Reported, Not Alarmed, Minor, Major, or Critical
alarm severities that you set to cause output closure. For example, if the trigger is set to Minor, a
Minor alarm or above is the trigger.
Remote NE alarm severity: Same as the local NE alarm severity but applies to remote alarms only.
Chapter 2
Common Control Cards
"1.9 ONS 15454 ANSI Alarm Expansion
78-18343-02